94.0% of DC fast-charging attempts succeeded in a California Energy Commission (CEC) field-study analysis, while 96.4% of fast-charging ports were operational when checked. Those are two different measurements. Neither is a finding that California chargers met—or violated—the state's separate annual 97% uptime requirement.12
The figures come from CEC's report CEC-600-2026-034, listed as updated November 16, 2026. The commission used field tests conducted by UC Davis's Electric Vehicle Research Center between January 2024 and February 2026. Its publication summarizes 3,571 plug-in charge tests plus observations of 12,586 additional charging ports; those are different kinds of observations, not 16,157 charging attempts.13
What the California tests actually reported
| Charger type | Operational Rate at the test | Successful Charge Attempt Rate (SCAR) | Difference between reported figures |
|---|---|---|---|
| Level 2 | 96.2% | 93.1% | 3.1 percentage points |
| DC fast charging | 96.4% | 94.0% | 2.4 percentage points |
CEC's published field-study figures; differences are arithmetic comparisons of reported rates, not estimates of failure among operational ports.1
The Operational Rate describes the share of studied ports functioning at the time of testing. The separately reported Successful Charge Attempt Rate, or SCAR, captures problems encountered when trying to charge, including payment and communication failures between the charger and vehicle.1
That distinction is useful for drivers: a port that appears operational during an inspection is not necessarily the same as a charge attempt that successfully starts. But the difference between the two headline percentages cannot be read as the probability that an otherwise operational port will fail. The published summary does not reconcile the underlying measurement denominators sufficiently to support that calculation.1
The study is also an interim snapshot. CEC says it commissioned field testing while continuous uptime data needed for its longer-term assessment were not yet available. It reports no statistically significant Operational Rate difference between the community categories it analyzed, which does not establish that every neighborhood or charging network performs identically.1
Why 94% success is not a 97% compliance failure
California's current EV Charger Data and Reliability Standards impose a 97% per-port uptime requirement on a defined group of publicly funded DC fast chargers installed on or after January 1, 2024, subject to exceptions. The requirement runs for six years and accounts for specified excluded downtime. Level 2 chargers are excluded from this uptime performance standard. It is not a threshold applied indiscriminately to every charging port in the study.2
Crucially, the rule assesses port uptime over time, while the newly reported figures come from field observations and plug-in tests. CEC's reporting framework calls for continuing charger data; the first semiannual reliability report for the specified earlier-installation reporting cohort is due January 31, 2027, covering July–December 2026. The November field-study figures cannot substitute for those compliance records.24
CEC cautiously suggests the tested network may have improved compared with previous studies, but acknowledges that the methodologies differ. It does not establish a comparable year-over-year improvement rate in its published summary.1
For a broader explanation of why charger uptime, first-attempt success and failed driver visits are not interchangeable, see ATC's public-charging reliability metrics guide. This new field study adds one specific California measurement; it does not answer which individual station a driver can rely on today.
Sources
Footnotes
-
California Energy Commission, “Results of Field Tests of California’s Electric Vehicle Charging Network Conducted Under Assembly Bill 2061,” CEC-600-2026-034 — official publication listing and abstract, updated November 16, 2026; original field tests January 2024–February 2026, attributed to UC Davis. https://www.energy.ca.gov/publications/2026/results-field-tests-californias-electric-vehicle-charging-network-conducted. Supports the reported rates, sample categories and qualified agency interpretations. The linked 26-page staff report and one-page Appendix B were not accessible for independent inspection in this M20 run; no per-metric denominator, confidence interval or sampling method is claimed beyond the abstract. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7
-
California Energy Commission, “EV Charger Performance Standards and Uptime Reporting Regulations” — current regulator guidance identifying the covered publicly funded DCFC cohort, 97% per-port standard, Level 2 exclusion, downtime exceptions and first semiannual reporting date. https://www.energy.ca.gov/programs-and-topics/programs/clean-transportation-program/ev-charger-data-and-reliability-1. A performance obligation does not measure the field study's sample. ↩ ↩2 ↩3
-
California Energy Commission, “Energy Commission Publications” — current official publications index listing report CEC-600-2026-034 updated November 16, 2026. https://www.energy.ca.gov/data-reports/all-publications/energy-commission-publications. An update date does not prove the exact first-publication time. ↩
-
California Energy Commission, “EV Charger Data and Reliability Standards: Data Submission Guidance” — current regulator reporting overview and 2025 framework for inventory/uptime reporting. https://www.energy.ca.gov/programs-and-topics/programs/clean-transportation-program/zev-infrastructure-data-reporting/ev. Does not verify field-test sub-sample denominators or real-time site availability. ↩